When configuring your radios you must also check your base station settings. Confirm the baud rate matches your radio setting of 57600.
- To reset or reconfigure your RTK radios, complete the following steps:
- Download and extract SikRadio Program
- Plug in the first radio into the computer using a USB cable.
- Open SikRadio program
- Select the established COM port. It is usually the second port if you have only the radio plugged in.
- Set Baud rate to 57600
- Select Load Settings
- Note: If you get the following error message, refer to the troubleshooting steps below:
- Note: If you get the following error message, refer to the troubleshooting steps below:
- Select “Reset To Defaults”
- Once all the fields are populated, confirm they match the following:
- Baud: 57
- AirSpeed: 64
- Min Freq: 902000 (only if using 915Mhz radios)
- Mavlink: RawData
- Select “Save Settings”
- Once done saving, unplug the first radio and plug in the second radio.
- Repeat steps 2-7 for the second radio.
- Unplug the second radio once finished
Troubleshooting
- Set Baud rate to 38400
- Select ""Reset to Default""
- Note After resetting to default you may see this error message:
- If so, hit the OK button on the message and change the baud rate in the ComPort section at the top of the window to 57600
- Note After resetting to default you may see this error message:
- Select ""Load Settings""
- Once all the fields are populated, confirm they match the following:
- Baud: 57
- AirSpeed: 64
- Min Freq: 902000 (only if using 915Mhz radios)
- Mavlink: RawData
- Select “Save Settings